{"formats":[{"name":"JSON","format":"json","url":"\/downloads\/2026\/code-json\/45.2-814.json"},{"name":"Plain Text","format":"text","url":"\/downloads\/2026\/code-text\/45.2-814.txt"},{"name":"XML","format":"xml","url":"\/downloads\/2026\/code-xml\/45.2-814.xml"},{"name":"HTML","format":"html","url":"\/downloads\/2026\/code-html\/45.2-814.html"}],"law_id":364486,"edition_id":2,"section_id":364486,"structure_id":52029,"section_number":"45.2-814","catch_line":" Inspection of electrical equipment and wiring; checking and testing methane monitors","history":"1966, c. 594, \u00a7 45.1-85; 1978, c. 118; 1993, c. 442; 1994, c. 28, \u00a7 45.1-161.195; 1996, c. 774; 1999, c. 256; 2005, c. 3; 2021, Sp. Sess. I, c. 387.","full_text":"A\n\nElectrical equipment and wiring shall be inspected by a certified person at least weekly if it is located underground and at least monthly if it is located on the surface. Such equipment and wiring shall be inspected more often if doing so is necessary to ensure safe operating conditions. Any hazardous condition that is found shall be promptly corrected or the equipment or wiring shall be removed from service. Records of such inspections shall be maintained at the mine for a period of one year.\n\nB\n\nA functional check of methane monitors on electrical face equipment shall be conducted to determine whether such monitors are de-energizing the electrical face equipment properly. Such check shall be (i) made on each production shift, (ii) conducted by the equipment operator in the presence of a mine foreman, and (iii) recorded in the on-shift report of the mine foreman.\n\nC\n\nTo determine the accuracy and operation of methane monitors on electrical face equipment, weekly calibration tests of such monitors shall be conducted with a known mixture of methane at the flow rate recommended by the methane monitor manufacturer. A record of the results shall be maintained.\n\nD\n\nRequired methane monitors shall be maintained in permissible and proper operating condition.\n\n","order_by":null,"text":{"0":{"id":1357927,"text":"Electrical equipment and wiring shall be inspected by a certified person at least weekly if it is located underground and at least monthly if it is located on the surface. Such equipment and wiring shall be inspected more often if doing so is necessary to ensure safe operating conditions. Any hazardous condition that is found shall be promptly corrected or the equipment or wiring shall be removed from service. Records of such inspections shall be maintained at the mine for a period of one year.","type":"section","prefixes":["A"],"prefix":"A","entire_prefix":"A","prefix_anchor":"A","level":1,"next_prefix":"B"},"1":{"id":1357928,"text":"A functional check of methane monitors on electrical face equipment shall be conducted to determine whether such monitors are de-energizing the electrical face equipment properly. Such check shall be (i) made on each production shift, (ii) conducted by the equipment operator in the presence of a mine foreman, and (iii) recorded in the on-shift report of the mine foreman.","type":"section","prefixes":["B"],"prefix":"B","entire_prefix":"B","prefix_anchor":"B","level":1,"prior_prefix":"A","next_prefix":"C"},"2":{"id":1357929,"text":"To determine the accuracy and operation of methane monitors on electrical face equipment, weekly calibration tests of such monitors shall be conducted with a known mixture of methane at the flow rate recommended by the methane monitor manufacturer. A record of the results shall be maintained.","type":"section","prefixes":["C"],"prefix":"C","entire_prefix":"C","prefix_anchor":"C","level":1,"prior_prefix":"B","next_prefix":"D"},"3":{"id":1357930,"text":"Required methane monitors shall be maintained in permissible and proper operating condition.","type":"section","prefixes":["D"],"prefix":"D","entire_prefix":"D","prefix_anchor":"D","level":1,"prior_prefix":"C"}},"ancestry":[{"id":52029,"edition_id":2,"name":"Electricity","identifier":"2","label":"article","depth":5,"order_by":2,"parent_id":52027,"metadata":{"child_laws":15,"child_structures":0},"date_created":"2026-08-02 02:52:18","date_modified":"2026-08-02 12:33:50","permalink":{"id":1450443,"object_type":"structure","relational_id":52029,"identifier":"2","token":"45.2\/II\/B\/8\/2","url":"\/45.2\/II\/B\/8\/2\/","edition_id":2,"permalink":0,"preferred":1}},{"id":52027,"edition_id":2,"name":"Requirements Applicable to Underground Coal Mines; Electricity, Safety, Etc","identifier":"8","label":"chapter","depth":4,"order_by":2,"parent_id":52016,"metadata":{"child_laws":64,"child_structures":6},"date_created":"2026-08-02 02:52:18","date_modified":"2026-08-02 12:33:49","permalink":{"id":1450427,"object_type":"structure","relational_id":52027,"identifier":"8","token":"45.2\/II\/B\/8","url":"\/45.2\/II\/B\/8\/","edition_id":2,"permalink":0,"preferred":1}},{"id":52016,"edition_id":2,"name":"Underground Coal Mines","identifier":"B","label":"part","depth":3,"order_by":2,"parent_id":51931,"metadata":{"child_laws":141,"child_structures":17},"date_created":"2026-08-02 02:52:10","date_modified":"2026-08-02 12:33:40","permalink":{"id":1450097,"object_type":"structure","relational_id":52016,"identifier":"B","token":"45.2\/II\/B","url":"\/45.2\/II\/B\/","edition_id":2,"permalink":0,"preferred":1}},{"id":51931,"edition_id":2,"name":"Coal Mining","identifier":"II","label":"subtitle","depth":2,"order_by":2,"parent_id":51927,"metadata":{"child_laws":337,"child_structures":56},"date_created":"2026-08-02 02:51:17","date_modified":"2026-08-02 12:33:33","permalink":{"id":1449649,"object_type":"structure","relational_id":51931,"identifier":"II","token":"45.2\/II","url":"\/45.2\/II\/","edition_id":2,"permalink":0,"preferred":1}},{"id":51927,"edition_id":2,"name":"Mines, Minerals, and Energy","identifier":"45.2","label":"title","depth":1,"order_by":99,"parent_id":null,"metadata":{"child_laws":627,"child_structures":120},"date_created":"2026-08-02 02:51:17","date_modified":"2026-08-02 12:33:32","permalink":{"id":1449541,"object_type":"structure","relational_id":51927,"identifier":"45.2","token":"45.2","url":"\/45.2\/","edition_id":2,"permalink":0,"preferred":1}}],"structure_contents":[{"id":364475,"structure_id":52029,"section_number":"45.2-803","catch_line":" Surface electrical installations","url":"\/45.2-803\/","token":"45.2\/II\/B\/8\/2\/45.2-803","metadata":false},{"id":364476,"structure_id":52029,"section_number":"45.2-804","catch_line":" Surface transformers","url":"\/45.2-804\/","token":"45.2\/II\/B\/8\/2\/45.2-804","metadata":false},{"id":364477,"structure_id":52029,"section_number":"45.2-805","catch_line":" Underground transformers","url":"\/45.2-805\/","token":"45.2\/II\/B\/8\/2\/45.2-805","metadata":false},{"id":364478,"structure_id":52029,"section_number":"45.2-806","catch_line":" Stations and substations","url":"\/45.2-806\/","token":"45.2\/II\/B\/8\/2\/45.2-806","metadata":false},{"id":364479,"structure_id":52029,"section_number":"45.2-807","catch_line":" Power circuits","url":"\/45.2-807\/","token":"45.2\/II\/B\/8\/2\/45.2-807","metadata":false},{"id":364480,"structure_id":52029,"section_number":"45.2-808","catch_line":" Trolley wires and feeder wires","url":"\/45.2-808\/","token":"45.2\/II\/B\/8\/2\/45.2-808","metadata":false},{"id":364481,"structure_id":52029,"section_number":"45.2-809","catch_line":" Grounding","url":"\/45.2-809\/","token":"45.2\/II\/B\/8\/2\/45.2-809","metadata":false},{"id":364482,"structure_id":52029,"section_number":"45.2-810","catch_line":" Circuit breakers and switches","url":"\/45.2-810\/","token":"45.2\/II\/B\/8\/2\/45.2-810","metadata":false},{"id":364483,"structure_id":52029,"section_number":"45.2-811","catch_line":" Communication systems","url":"\/45.2-811\/","token":"45.2\/II\/B\/8\/2\/45.2-811","metadata":false},{"id":364484,"structure_id":52029,"section_number":"45.2-812","catch_line":" Electrical equipment","url":"\/45.2-812\/","token":"45.2\/II\/B\/8\/2\/45.2-812","metadata":false},{"id":364485,"structure_id":52029,"section_number":"45.2-813","catch_line":" Trailing cables","url":"\/45.2-813\/","token":"45.2\/II\/B\/8\/2\/45.2-813","metadata":false},{"id":364486,"structure_id":52029,"section_number":"45.2-814","catch_line":" Inspection of electrical equipment and wiring; checking and testing methane monitors","url":"\/45.2-814\/","token":"45.2\/II\/B\/8\/2\/45.2-814","metadata":false},{"id":364487,"structure_id":52029,"section_number":"45.2-815","catch_line":" Repairs to circuits and electric equipment","url":"\/45.2-815\/","token":"45.2\/II\/B\/8\/2\/45.2-815","metadata":false},{"id":364488,"structure_id":52029,"section_number":"45.2-816","catch_line":" Underground illumination","url":"\/45.2-816\/","token":"45.2\/II\/B\/8\/2\/45.2-816","metadata":false},{"id":364489,"structure_id":52029,"section_number":"45.2-817","catch_line":" Inspection of electric illumination equipment","url":"\/45.2-817\/","token":"45.2\/II\/B\/8\/2\/45.2-817","metadata":false}],"previous_section":{"id":364485,"structure_id":52029,"section_number":"45.2-813","catch_line":" Trailing cables","url":"\/45.2-813\/","token":"45.2\/II\/B\/8\/2\/45.2-813","metadata":false},"next_section":{"id":364487,"structure_id":52029,"section_number":"45.2-815","catch_line":" Repairs to circuits and electric equipment","url":"\/45.2-815\/","token":"45.2\/II\/B\/8\/2\/45.2-815","metadata":false},"metadata":false,"official_url":"https:\/\/law.lis.virginia.gov\/vacode\/45.2-814\/","history_text":"<p>This law was first created in 1966. The record of its establishment is cataloged in chapter 594 of that year\u2019s edition of \u201cActs of Assembly,\u201d the annual state publication listing all changes made to the Code of Virginia in that year. Unfortunately, the 1966 \u201cActs\u201d aren\u2019t available online. It has been modified 6 times. Those modifications are cataloged by \u201cThe Acts of Assembly,\u201d a state publication, by year and chapter. Those modifications that can be read on the General Assembly\u2019s website will be linked accordingly. Those modifications are as follows: in 1978, chapter 118; in 1993, chapter 442; in 1994, chapter <a href=\"https:\/\/legacylis.virginia.gov\/cgi-bin\/legp604.exe?941+ful+CHAP0028\">28<\/a>; in 1996, chapter <a href=\"https:\/\/legacylis.virginia.gov\/cgi-bin\/legp604.exe?961+ful+CHAP0774\">774<\/a>; in 1999, chapter <a href=\"https:\/\/legacylis.virginia.gov\/cgi-bin\/legp604.exe?991+ful+CHAP0256\">256<\/a>; in 2005, chapter <a href=\"https:\/\/legacylis.virginia.gov\/cgi-bin\/legp604.exe?051+ful+CHAP0003\">3<\/a>.<\/p>","references":false,"refers_to":false,"permalink":{"id":1450489,"object_type":"law","relational_id":364486,"identifier":"45.2-814","token":"45.2\/II\/B\/8\/2\/45.2-814","url":"\/45.2-814\/","edition_id":2,"permalink":0,"preferred":1},"url":"\/45.2-814\/","token":"45.2\/II\/B\/8\/2\/45.2-814","dublin_core":{"Title":" Inspection of electrical equipment and wiring; checking and testing methane monitors","Type":"Text","Format":"text\/html","Identifier":"\u00a7 45.2-814","Relation":"Code of Virginia"},"html":"\n\t\t\t\t\t\t<section id=\"A\"><p><span class=\"prefix-number\">A.<\/span> Electrical equipment and wiring shall be inspected by a certified person at least weekly if it is located underground and at least monthly if it is located on the surface. Such equipment and wiring shall be inspected more often if doing so is necessary to ensure safe operating conditions. Any hazardous condition that is found shall be promptly corrected or the equipment or wiring shall be removed from service. Records of such inspections shall be maintained at the mine for a period of one year. <a id=\"paragraph-1357927\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-814\/#A\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"B\"><p><span class=\"prefix-number\">B.<\/span> A functional check of methane monitors on electrical face equipment shall be conducted to determine whether such monitors are de-energizing the electrical face equipment properly. Such check shall be (i) made on each production shift, (ii) conducted by the equipment operator in the presence of a mine <span class=\"dictionary\">foreman<\/span>, and (iii) recorded in the on-shift report of the mine <span class=\"dictionary\">foreman<\/span>. <a id=\"paragraph-1357928\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-814\/#B\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"C\"><p><span class=\"prefix-number\">C.<\/span> To determine the accuracy and operation of methane monitors on electrical face equipment, weekly calibration tests of such monitors shall be conducted with a known mixture of methane at the flow rate recommended by the methane monitor manufacturer. A record of the results shall be maintained. <a id=\"paragraph-1357929\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-814\/#C\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"D\"><p><span class=\"prefix-number\">D.<\/span> Required methane monitors shall be maintained in permissible and proper operating condition. <a id=\"paragraph-1357930\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-814\/#D\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>","plain_text":"                                 CODE OF VIRGINIA\n\n INSPECTION OF ELECTRICAL EQUIPMENT AND WIRING; CHECKING AND TESTING METHANE\nMONITORS (\u00a7 45.2-814)\n\nA. Electrical equipment and wiring shall be inspected by a certified person at\nleast weekly if it is located underground and at least monthly if it is located\non the surface. Such equipment and wiring shall be inspected more often if doing\nso is necessary to ensure safe operating conditions. Any hazardous condition\nthat is found shall be promptly corrected or the equipment or wiring shall be\nremoved from service. Records of such inspections shall be maintained at the\nmine for a period of one year.\n\nB. A functional check of methane monitors on electrical face equipment shall be\nconducted to determine whether such monitors are de-energizing the electrical\nface equipment properly. Such check shall be (i) made on each production shift,\n(ii) conducted by the equipment operator in the presence of a mine foreman, and\n(iii) recorded in the on-shift report of the mine foreman.\n\nC. To determine the accuracy and operation of methane monitors on electrical\nface equipment, weekly calibration tests of such monitors shall be conducted\nwith a known mixture of methane at the flow rate recommended by the methane\nmonitor manufacturer. A record of the results shall be maintained.\n\nD. Required methane monitors shall be maintained in permissible and proper\noperating condition.\n\nHISTORY: 1966, c. 594, \u00a7 45.1-85; 1978, c. 118; 1993, c. 442; 1994, c. 28, \u00a7\n45.1-161.195; 1996, c. 774; 1999, c. 256; 2005, c. 3; 2021, Sp. Sess. I, c. 387.","edition":{"id":2,"name":"2026","slug":"2026","date_created":"2026-07-16 18:40:23","date_modified":"2026-08-02 15:14:36","current":1,"order_by":2,"last_import":"2026-08-02 12:37:30"}}