{"formats":[{"name":"JSON","format":"json","url":"\/downloads\/2026\/code-json\/45.2-811.json"},{"name":"Plain Text","format":"text","url":"\/downloads\/2026\/code-text\/45.2-811.txt"},{"name":"XML","format":"xml","url":"\/downloads\/2026\/code-xml\/45.2-811.xml"},{"name":"HTML","format":"html","url":"\/downloads\/2026\/code-html\/45.2-811.html"}],"law_id":364483,"edition_id":2,"section_id":364483,"structure_id":52029,"section_number":"45.2-811","catch_line":" Communication systems","history":"Code 1950, \u00a7 45-82.4; 1954, c. 191; 1966, c. 594, \u00a7 45.1-81; 1978, c. 118; 1979, c. 315; 1994, c. 28, \u00a7 45.1-161.191; 1996, c. 774; 1999, c. 256; 2021, Sp. Sess. I, c. 387.","full_text":"A\n\nTelephone service or equivalent two-way communication facilities shall be provided between the top and each landing of each main shaft or slope. A telephone or equivalent two-way communication facility shall be located on the surface within 500 feet of each main portal and installed in either a building or a box-like structure that is designed to protect the facility from damage by inclement weather. At least one of these communication facilities shall be at a location where an authorized person who is always on duty when miners are underground can see or hear the facility and respond immediately in the event of an emergency.\n\nB\n\nTelephone lines, other than cables, shall be carried on insulators, installed on the opposite side from power or trolley wires, and insulated adequately where they cross power or trolley wires.\n\nC\n\nLightning arrestors shall be provided at each point where a telephone circuit enters the mine and at each telephone on the surface. Where the telephone circuit enters a building or structure, a lightning arrestor is required only at the point at which the circuit enters such building or structure.\n\nD\n\nIf a communication system other than telephones is used and its operation depends entirely upon power from the mine electric system, a means shall be provided to permit continued communication in the event the mine electric power fails or is cut off.\n\nE\n\nCommunication systems equipped with audible and visual signals that become operative when telephone communication is being established between the phones of the communication station on the surface and the underground working sections shall be provided.\n\nF\n\nThe Chief shall adopt regulations governing any disruption of communication in a mine.\n\n","order_by":null,"text":{"0":{"id":1357900,"text":"Telephone service or equivalent two-way communication facilities shall be provided between the top and each landing of each main shaft or slope. A telephone or equivalent two-way communication facility shall be located on the surface within 500 feet of each main portal and installed in either a building or a box-like structure that is designed to protect the facility from damage by inclement weather. At least one of these communication facilities shall be at a location where an authorized person who is always on duty when miners are underground can see or hear the facility and respond immediately in the event of an emergency.","type":"section","prefixes":["A"],"prefix":"A","entire_prefix":"A","prefix_anchor":"A","level":1,"next_prefix":"B"},"1":{"id":1357901,"text":"Telephone lines, other than cables, shall be carried on insulators, installed on the opposite side from power or trolley wires, and insulated adequately where they cross power or trolley wires.","type":"section","prefixes":["B"],"prefix":"B","entire_prefix":"B","prefix_anchor":"B","level":1,"prior_prefix":"A","next_prefix":"C"},"2":{"id":1357902,"text":"Lightning arrestors shall be provided at each point where a telephone circuit enters the mine and at each telephone on the surface. Where the telephone circuit enters a building or structure, a lightning arrestor is required only at the point at which the circuit enters such building or structure.","type":"section","prefixes":["C"],"prefix":"C","entire_prefix":"C","prefix_anchor":"C","level":1,"prior_prefix":"B","next_prefix":"D"},"3":{"id":1357903,"text":"If a communication system other than telephones is used and its operation depends entirely upon power from the mine electric system, a means shall be provided to permit continued communication in the event the mine electric power fails or is cut off.","type":"section","prefixes":["D"],"prefix":"D","entire_prefix":"D","prefix_anchor":"D","level":1,"prior_prefix":"C","next_prefix":"E"},"4":{"id":1357904,"text":"Communication systems equipped with audible and visual signals that become operative when telephone communication is being established between the phones of the communication station on the surface and the underground working sections shall be provided.","type":"section","prefixes":["E"],"prefix":"E","entire_prefix":"E","prefix_anchor":"E","level":1,"prior_prefix":"D","next_prefix":"F"},"5":{"id":1357905,"text":"The Chief shall adopt regulations governing any disruption of communication in a mine.","type":"section","prefixes":["F"],"prefix":"F","entire_prefix":"F","prefix_anchor":"F","level":1,"prior_prefix":"E"}},"ancestry":[{"id":52029,"edition_id":2,"name":"Electricity","identifier":"2","label":"article","depth":5,"order_by":2,"parent_id":52027,"metadata":{"child_laws":15,"child_structures":0},"date_created":"2026-08-02 02:52:18","date_modified":"2026-08-02 12:33:50","permalink":{"id":1450443,"object_type":"structure","relational_id":52029,"identifier":"2","token":"45.2\/II\/B\/8\/2","url":"\/45.2\/II\/B\/8\/2\/","edition_id":2,"permalink":0,"preferred":1}},{"id":52027,"edition_id":2,"name":"Requirements Applicable to Underground Coal Mines; Electricity, Safety, Etc","identifier":"8","label":"chapter","depth":4,"order_by":2,"parent_id":52016,"metadata":{"child_laws":64,"child_structures":6},"date_created":"2026-08-02 02:52:18","date_modified":"2026-08-02 12:33:49","permalink":{"id":1450427,"object_type":"structure","relational_id":52027,"identifier":"8","token":"45.2\/II\/B\/8","url":"\/45.2\/II\/B\/8\/","edition_id":2,"permalink":0,"preferred":1}},{"id":52016,"edition_id":2,"name":"Underground Coal Mines","identifier":"B","label":"part","depth":3,"order_by":2,"parent_id":51931,"metadata":{"child_laws":141,"child_structures":17},"date_created":"2026-08-02 02:52:10","date_modified":"2026-08-02 12:33:40","permalink":{"id":1450097,"object_type":"structure","relational_id":52016,"identifier":"B","token":"45.2\/II\/B","url":"\/45.2\/II\/B\/","edition_id":2,"permalink":0,"preferred":1}},{"id":51931,"edition_id":2,"name":"Coal Mining","identifier":"II","label":"subtitle","depth":2,"order_by":2,"parent_id":51927,"metadata":{"child_laws":337,"child_structures":56},"date_created":"2026-08-02 02:51:17","date_modified":"2026-08-02 12:33:33","permalink":{"id":1449649,"object_type":"structure","relational_id":51931,"identifier":"II","token":"45.2\/II","url":"\/45.2\/II\/","edition_id":2,"permalink":0,"preferred":1}},{"id":51927,"edition_id":2,"name":"Mines, Minerals, and Energy","identifier":"45.2","label":"title","depth":1,"order_by":99,"parent_id":null,"metadata":{"child_laws":627,"child_structures":120},"date_created":"2026-08-02 02:51:17","date_modified":"2026-08-02 12:33:32","permalink":{"id":1449541,"object_type":"structure","relational_id":51927,"identifier":"45.2","token":"45.2","url":"\/45.2\/","edition_id":2,"permalink":0,"preferred":1}}],"structure_contents":[{"id":364475,"structure_id":52029,"section_number":"45.2-803","catch_line":" Surface electrical installations","url":"\/45.2-803\/","token":"45.2\/II\/B\/8\/2\/45.2-803","metadata":false},{"id":364476,"structure_id":52029,"section_number":"45.2-804","catch_line":" Surface transformers","url":"\/45.2-804\/","token":"45.2\/II\/B\/8\/2\/45.2-804","metadata":false},{"id":364477,"structure_id":52029,"section_number":"45.2-805","catch_line":" Underground transformers","url":"\/45.2-805\/","token":"45.2\/II\/B\/8\/2\/45.2-805","metadata":false},{"id":364478,"structure_id":52029,"section_number":"45.2-806","catch_line":" Stations and substations","url":"\/45.2-806\/","token":"45.2\/II\/B\/8\/2\/45.2-806","metadata":false},{"id":364479,"structure_id":52029,"section_number":"45.2-807","catch_line":" Power circuits","url":"\/45.2-807\/","token":"45.2\/II\/B\/8\/2\/45.2-807","metadata":false},{"id":364480,"structure_id":52029,"section_number":"45.2-808","catch_line":" Trolley wires and feeder wires","url":"\/45.2-808\/","token":"45.2\/II\/B\/8\/2\/45.2-808","metadata":false},{"id":364481,"structure_id":52029,"section_number":"45.2-809","catch_line":" Grounding","url":"\/45.2-809\/","token":"45.2\/II\/B\/8\/2\/45.2-809","metadata":false},{"id":364482,"structure_id":52029,"section_number":"45.2-810","catch_line":" Circuit breakers and switches","url":"\/45.2-810\/","token":"45.2\/II\/B\/8\/2\/45.2-810","metadata":false},{"id":364483,"structure_id":52029,"section_number":"45.2-811","catch_line":" Communication systems","url":"\/45.2-811\/","token":"45.2\/II\/B\/8\/2\/45.2-811","metadata":false},{"id":364484,"structure_id":52029,"section_number":"45.2-812","catch_line":" Electrical equipment","url":"\/45.2-812\/","token":"45.2\/II\/B\/8\/2\/45.2-812","metadata":false},{"id":364485,"structure_id":52029,"section_number":"45.2-813","catch_line":" Trailing cables","url":"\/45.2-813\/","token":"45.2\/II\/B\/8\/2\/45.2-813","metadata":false},{"id":364486,"structure_id":52029,"section_number":"45.2-814","catch_line":" Inspection of electrical equipment and wiring; checking and testing methane monitors","url":"\/45.2-814\/","token":"45.2\/II\/B\/8\/2\/45.2-814","metadata":false},{"id":364487,"structure_id":52029,"section_number":"45.2-815","catch_line":" Repairs to circuits and electric equipment","url":"\/45.2-815\/","token":"45.2\/II\/B\/8\/2\/45.2-815","metadata":false},{"id":364488,"structure_id":52029,"section_number":"45.2-816","catch_line":" Underground illumination","url":"\/45.2-816\/","token":"45.2\/II\/B\/8\/2\/45.2-816","metadata":false},{"id":364489,"structure_id":52029,"section_number":"45.2-817","catch_line":" Inspection of electric illumination equipment","url":"\/45.2-817\/","token":"45.2\/II\/B\/8\/2\/45.2-817","metadata":false}],"previous_section":{"id":364482,"structure_id":52029,"section_number":"45.2-810","catch_line":" Circuit breakers and switches","url":"\/45.2-810\/","token":"45.2\/II\/B\/8\/2\/45.2-810","metadata":false},"next_section":{"id":364484,"structure_id":52029,"section_number":"45.2-812","catch_line":" Electrical equipment","url":"\/45.2-812\/","token":"45.2\/II\/B\/8\/2\/45.2-812","metadata":false},"metadata":false,"official_url":"https:\/\/law.lis.virginia.gov\/vacode\/45.2-811\/","history_text":"<p>The record of this law\u2019s original creation isn\u2019t available online. It has been modified 7 times. Those modifications are cataloged by \u201cThe Acts of Assembly,\u201d a state publication, by year and chapter. Those modifications that can be read on the General Assembly\u2019s website will be linked accordingly. Those modifications are as follows: in 1954, chapter 191; in 1966, chapter 594; in 1978, chapter 118; in 1979, chapter 315; in 1994, chapter <a href=\"https:\/\/legacylis.virginia.gov\/cgi-bin\/legp604.exe?941+ful+CHAP0028\">28<\/a>; in 1996, chapter <a href=\"https:\/\/legacylis.virginia.gov\/cgi-bin\/legp604.exe?961+ful+CHAP0774\">774<\/a>; in 1999, chapter <a href=\"https:\/\/legacylis.virginia.gov\/cgi-bin\/legp604.exe?991+ful+CHAP0256\">256<\/a>.<\/p>","references":false,"refers_to":false,"permalink":{"id":1450477,"object_type":"law","relational_id":364483,"identifier":"45.2-811","token":"45.2\/II\/B\/8\/2\/45.2-811","url":"\/45.2-811\/","edition_id":2,"permalink":0,"preferred":1},"url":"\/45.2-811\/","token":"45.2\/II\/B\/8\/2\/45.2-811","dublin_core":{"Title":" Communication systems","Type":"Text","Format":"text\/html","Identifier":"\u00a7 45.2-811","Relation":"Code of Virginia"},"html":"\n\t\t\t\t\t\t<section id=\"A\"><p><span class=\"prefix-number\">A.<\/span> Telephone service or equivalent two-way communication facilities shall be provided between the top and each landing of each main shaft or slope. A telephone or equivalent two-way communication facility shall be located on the surface within 500 feet of each main portal and installed in either a building or a box-like structure that is designed to protect the facility from damage by inclement weather. At least one of these communication facilities shall be at a location where an authorized person who is always on duty when miners are underground can see or hear the facility and respond immediately in the event of an emergency. <a id=\"paragraph-1357900\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-811\/#A\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"B\"><p><span class=\"prefix-number\">B.<\/span> Telephone lines, other than cables, shall be carried on insulators, installed on the opposite side from power or trolley wires, and insulated adequately where they cross power or trolley wires. <a id=\"paragraph-1357901\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-811\/#B\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"C\"><p><span class=\"prefix-number\">C.<\/span> Lightning arrestors shall be provided at each point where a telephone <span class=\"dictionary\">circuit<\/span> enters the mine and at each telephone on the surface. Where the telephone <span class=\"dictionary\">circuit<\/span> enters a building or structure, a lightning arrestor is required only at the point at which the <span class=\"dictionary\">circuit<\/span> enters such building or structure. <a id=\"paragraph-1357902\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-811\/#C\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"D\"><p><span class=\"prefix-number\">D.<\/span> If a communication system other than telephones is used and its operation depends entirely upon power from the mine electric system, a means shall be provided to permit continued communication in the event the mine electric power fails or is cut off. <a id=\"paragraph-1357903\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-811\/#D\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"E\"><p><span class=\"prefix-number\">E.<\/span> Communication systems equipped with audible and visual signals that become operative when telephone communication is being established between the phones of the communication station on the surface and the underground working sections shall be provided. <a id=\"paragraph-1357904\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-811\/#E\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"F\"><p><span class=\"prefix-number\">F.<\/span> The <span class=\"dictionary\">Chief<\/span> shall adopt regulations governing any disruption of communication in a mine. <a id=\"paragraph-1357905\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-811\/#F\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>","plain_text":"                                 CODE OF VIRGINIA\n\n COMMUNICATION SYSTEMS (\u00a7 45.2-811)\n\nA. Telephone service or equivalent two-way communication facilities shall be\nprovided between the top and each landing of each main shaft or slope. A\ntelephone or equivalent two-way communication facility shall be located on the\nsurface within 500 feet of each main portal and installed in either a building\nor a box-like structure that is designed to protect the facility from damage by\ninclement weather. At least one of these communication facilities shall be at a\nlocation where an authorized person who is always on duty when miners are\nunderground can see or hear the facility and respond immediately in the event of\nan emergency.\n\nB. Telephone lines, other than cables, shall be carried on insulators, installed\non the opposite side from power or trolley wires, and insulated adequately where\nthey cross power or trolley wires.\n\nC. Lightning arrestors shall be provided at each point where a telephone circuit\nenters the mine and at each telephone on the surface. Where the telephone\ncircuit enters a building or structure, a lightning arrestor is required only at\nthe point at which the circuit enters such building or structure.\n\nD. If a communication system other than telephones is used and its operation\ndepends entirely upon power from the mine electric system, a means shall be\nprovided to permit continued communication in the event the mine electric power\nfails or is cut off.\n\nE. Communication systems equipped with audible and visual signals that become\noperative when telephone communication is being established between the phones\nof the communication station on the surface and the underground working sections\nshall be provided.\n\nF. The Chief shall adopt regulations governing any disruption of communication\nin a mine.\n\nHISTORY: Code 1950, \u00a7 45-82.4; 1954, c. 191; 1966, c. 594, \u00a7 45.1-81; 1978, c.\n118; 1979, c. 315; 1994, c. 28, \u00a7 45.1-161.191; 1996, c. 774; 1999, c. 256;\n2021, Sp. Sess. I, c. 387.","edition":{"id":2,"name":"2026","slug":"2026","date_created":"2026-07-16 18:40:23","date_modified":"2026-08-02 15:14:36","current":1,"order_by":2,"last_import":"2026-08-02 12:37:30"}}