{"formats":[{"name":"JSON","format":"json","url":"\/downloads\/2026\/code-json\/45.2-804.json"},{"name":"Plain Text","format":"text","url":"\/downloads\/2026\/code-text\/45.2-804.txt"},{"name":"XML","format":"xml","url":"\/downloads\/2026\/code-xml\/45.2-804.xml"},{"name":"HTML","format":"html","url":"\/downloads\/2026\/code-html\/45.2-804.html"}],"law_id":364476,"edition_id":2,"section_id":364476,"structure_id":52029,"section_number":"45.2-804","catch_line":" Surface transformers","history":"Code 1950, \u00a7 45-82.2; 1954, c. 191; 1966, c. 594, \u00a7 45.1-76; 1994, c. 28, \u00a7 45.1-161.182; 2021, Sp. Sess. I, c. 387.","full_text":"A\n\nAny surface transformer that is not isolated by being elevated at least eight feet above the ground shall be enclosed in a transformer house or surrounded by a suitable fence at least six feet high. If the enclosure or fence is of metal, it shall be grounded effectively. The door to the enclosure or the gate to the fence shall be kept locked at all times unless a person who is authorized to enter the gate or enclosure is present.\n\nB\n\nAny surface transformer that contains flammable oil and is installed near a mine opening, in or near a combustible building, or at any other place where such transformer presents a fire hazard shall be provided with a means to drain or to confine the oil in the event of a rupture of the transformer casing.\n\n","order_by":null,"text":{"0":{"id":1357854,"text":"Any surface transformer that is not isolated by being elevated at least eight feet above the ground shall be enclosed in a transformer house or surrounded by a suitable fence at least six feet high. If the enclosure or fence is of metal, it shall be grounded effectively. The door to the enclosure or the gate to the fence shall be kept locked at all times unless a person who is authorized to enter the gate or enclosure is present.","type":"section","prefixes":["A"],"prefix":"A","entire_prefix":"A","prefix_anchor":"A","level":1,"next_prefix":"B"},"1":{"id":1357855,"text":"Any surface transformer that contains flammable oil and is installed near a mine opening, in or near a combustible building, or at any other place where such transformer presents a fire hazard shall be provided with a means to drain or to confine the oil in the event of a rupture of the transformer casing.","type":"section","prefixes":["B"],"prefix":"B","entire_prefix":"B","prefix_anchor":"B","level":1,"prior_prefix":"A"}},"ancestry":[{"id":52029,"edition_id":2,"name":"Electricity","identifier":"2","label":"article","depth":5,"order_by":2,"parent_id":52027,"metadata":{"child_laws":15,"child_structures":0},"date_created":"2026-08-02 02:52:18","date_modified":"2026-08-02 12:33:50","permalink":{"id":1450443,"object_type":"structure","relational_id":52029,"identifier":"2","token":"45.2\/II\/B\/8\/2","url":"\/45.2\/II\/B\/8\/2\/","edition_id":2,"permalink":0,"preferred":1}},{"id":52027,"edition_id":2,"name":"Requirements Applicable to Underground Coal Mines; Electricity, Safety, Etc","identifier":"8","label":"chapter","depth":4,"order_by":2,"parent_id":52016,"metadata":{"child_laws":64,"child_structures":6},"date_created":"2026-08-02 02:52:18","date_modified":"2026-08-02 12:33:49","permalink":{"id":1450427,"object_type":"structure","relational_id":52027,"identifier":"8","token":"45.2\/II\/B\/8","url":"\/45.2\/II\/B\/8\/","edition_id":2,"permalink":0,"preferred":1}},{"id":52016,"edition_id":2,"name":"Underground Coal Mines","identifier":"B","label":"part","depth":3,"order_by":2,"parent_id":51931,"metadata":{"child_laws":141,"child_structures":17},"date_created":"2026-08-02 02:52:10","date_modified":"2026-08-02 12:33:40","permalink":{"id":1450097,"object_type":"structure","relational_id":52016,"identifier":"B","token":"45.2\/II\/B","url":"\/45.2\/II\/B\/","edition_id":2,"permalink":0,"preferred":1}},{"id":51931,"edition_id":2,"name":"Coal Mining","identifier":"II","label":"subtitle","depth":2,"order_by":2,"parent_id":51927,"metadata":{"child_laws":337,"child_structures":56},"date_created":"2026-08-02 02:51:17","date_modified":"2026-08-02 12:33:33","permalink":{"id":1449649,"object_type":"structure","relational_id":51931,"identifier":"II","token":"45.2\/II","url":"\/45.2\/II\/","edition_id":2,"permalink":0,"preferred":1}},{"id":51927,"edition_id":2,"name":"Mines, Minerals, and Energy","identifier":"45.2","label":"title","depth":1,"order_by":99,"parent_id":null,"metadata":{"child_laws":627,"child_structures":120},"date_created":"2026-08-02 02:51:17","date_modified":"2026-08-02 12:33:32","permalink":{"id":1449541,"object_type":"structure","relational_id":51927,"identifier":"45.2","token":"45.2","url":"\/45.2\/","edition_id":2,"permalink":0,"preferred":1}}],"structure_contents":[{"id":364475,"structure_id":52029,"section_number":"45.2-803","catch_line":" Surface electrical installations","url":"\/45.2-803\/","token":"45.2\/II\/B\/8\/2\/45.2-803","metadata":false},{"id":364476,"structure_id":52029,"section_number":"45.2-804","catch_line":" Surface transformers","url":"\/45.2-804\/","token":"45.2\/II\/B\/8\/2\/45.2-804","metadata":false},{"id":364477,"structure_id":52029,"section_number":"45.2-805","catch_line":" Underground transformers","url":"\/45.2-805\/","token":"45.2\/II\/B\/8\/2\/45.2-805","metadata":false},{"id":364478,"structure_id":52029,"section_number":"45.2-806","catch_line":" Stations and substations","url":"\/45.2-806\/","token":"45.2\/II\/B\/8\/2\/45.2-806","metadata":false},{"id":364479,"structure_id":52029,"section_number":"45.2-807","catch_line":" Power circuits","url":"\/45.2-807\/","token":"45.2\/II\/B\/8\/2\/45.2-807","metadata":false},{"id":364480,"structure_id":52029,"section_number":"45.2-808","catch_line":" Trolley wires and feeder wires","url":"\/45.2-808\/","token":"45.2\/II\/B\/8\/2\/45.2-808","metadata":false},{"id":364481,"structure_id":52029,"section_number":"45.2-809","catch_line":" Grounding","url":"\/45.2-809\/","token":"45.2\/II\/B\/8\/2\/45.2-809","metadata":false},{"id":364482,"structure_id":52029,"section_number":"45.2-810","catch_line":" Circuit breakers and switches","url":"\/45.2-810\/","token":"45.2\/II\/B\/8\/2\/45.2-810","metadata":false},{"id":364483,"structure_id":52029,"section_number":"45.2-811","catch_line":" Communication systems","url":"\/45.2-811\/","token":"45.2\/II\/B\/8\/2\/45.2-811","metadata":false},{"id":364484,"structure_id":52029,"section_number":"45.2-812","catch_line":" Electrical equipment","url":"\/45.2-812\/","token":"45.2\/II\/B\/8\/2\/45.2-812","metadata":false},{"id":364485,"structure_id":52029,"section_number":"45.2-813","catch_line":" Trailing cables","url":"\/45.2-813\/","token":"45.2\/II\/B\/8\/2\/45.2-813","metadata":false},{"id":364486,"structure_id":52029,"section_number":"45.2-814","catch_line":" Inspection of electrical equipment and wiring; checking and testing methane monitors","url":"\/45.2-814\/","token":"45.2\/II\/B\/8\/2\/45.2-814","metadata":false},{"id":364487,"structure_id":52029,"section_number":"45.2-815","catch_line":" Repairs to circuits and electric equipment","url":"\/45.2-815\/","token":"45.2\/II\/B\/8\/2\/45.2-815","metadata":false},{"id":364488,"structure_id":52029,"section_number":"45.2-816","catch_line":" Underground illumination","url":"\/45.2-816\/","token":"45.2\/II\/B\/8\/2\/45.2-816","metadata":false},{"id":364489,"structure_id":52029,"section_number":"45.2-817","catch_line":" Inspection of electric illumination equipment","url":"\/45.2-817\/","token":"45.2\/II\/B\/8\/2\/45.2-817","metadata":false}],"previous_section":{"id":364475,"structure_id":52029,"section_number":"45.2-803","catch_line":" Surface electrical installations","url":"\/45.2-803\/","token":"45.2\/II\/B\/8\/2\/45.2-803","metadata":false},"next_section":{"id":364477,"structure_id":52029,"section_number":"45.2-805","catch_line":" Underground transformers","url":"\/45.2-805\/","token":"45.2\/II\/B\/8\/2\/45.2-805","metadata":false},"metadata":false,"official_url":"https:\/\/law.lis.virginia.gov\/vacode\/45.2-804\/","history_text":"<p>The record of this law\u2019s original creation isn\u2019t available online. It has been modified 3 times. Those modifications are cataloged by \u201cThe Acts of Assembly,\u201d a state publication, by year and chapter. Those modifications that can be read on the General Assembly\u2019s website will be linked accordingly. Those modifications are as follows: in 1954, chapter 191; in 1966, chapter 594; in 1994, chapter <a href=\"https:\/\/legacylis.virginia.gov\/cgi-bin\/legp604.exe?941+ful+CHAP0028\">28<\/a>.<\/p>","references":false,"refers_to":false,"permalink":{"id":1450449,"object_type":"law","relational_id":364476,"identifier":"45.2-804","token":"45.2\/II\/B\/8\/2\/45.2-804","url":"\/45.2-804\/","edition_id":2,"permalink":0,"preferred":1},"url":"\/45.2-804\/","token":"45.2\/II\/B\/8\/2\/45.2-804","dublin_core":{"Title":" Surface transformers","Type":"Text","Format":"text\/html","Identifier":"\u00a7 45.2-804","Relation":"Code of Virginia"},"html":"\n\t\t\t\t\t\t<section id=\"A\"><p><span class=\"prefix-number\">A.<\/span> Any surface transformer that is not isolated by being elevated at least eight feet above the ground shall be enclosed in a transformer house or surrounded by a suitable fence at least six feet high. If the enclosure or fence is of metal, it shall be grounded effectively. The door to the enclosure or the gate to the fence shall be kept locked at all times unless a person who is authorized to enter the gate or enclosure is present. <a id=\"paragraph-1357854\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-804\/#A\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"B\"><p><span class=\"prefix-number\">B.<\/span> Any surface transformer that contains flammable oil and is installed near a mine opening, in or near a combustible building, or at any other place where such transformer presents a fire hazard shall be provided with a means to drain or to confine the oil in the event of a rupture of the transformer casing. <a id=\"paragraph-1357855\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-804\/#B\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>","plain_text":"                                 CODE OF VIRGINIA\n\n SURFACE TRANSFORMERS (\u00a7 45.2-804)\n\nA. Any surface transformer that is not isolated by being elevated at least eight\nfeet above the ground shall be enclosed in a transformer house or surrounded by\na suitable fence at least six feet high. If the enclosure or fence is of metal,\nit shall be grounded effectively. The door to the enclosure or the gate to the\nfence shall be kept locked at all times unless a person who is authorized to\nenter the gate or enclosure is present.\n\nB. Any surface transformer that contains flammable oil and is installed near a\nmine opening, in or near a combustible building, or at any other place where\nsuch transformer presents a fire hazard shall be provided with a means to drain\nor to confine the oil in the event of a rupture of the transformer casing.\n\nHISTORY: Code 1950, \u00a7 45-82.2; 1954, c. 191; 1966, c. 594, \u00a7 45.1-76; 1994, c.\n28, \u00a7 45.1-161.182; 2021, Sp. Sess. I, c. 387.","edition":{"id":2,"name":"2026","slug":"2026","date_created":"2026-07-16 18:40:23","date_modified":"2026-08-02 15:14:36","current":1,"order_by":2,"last_import":"2026-08-02 12:37:30"}}